AAC Active Air Conditioning Direct Cooling Technology

The principle of active air conditioning direct cooling technology is to combine the air conditioning compressor with a fiber laser, compress the gaseous refrigerant into a high-temperature and high-pressure gaseous state through the air conditioning compressor, and send it to the condenser for cooling. After cooling, it becomes a medium temperature and high-pressure liquid refrigerant. The medium temperature liquid refrigerant is throttled and depressurized by an expansion valve, becoming a low-temperature and low-pressure gas-liquid mixture. It absorbs heat inside the laser and vaporizes, becoming a gaseous state, and then returns to the compressor for further compression and circulation for cooling. During heating, the four-way valve makes the flow direction of Freon in the condenser and evaporator opposite to that during cooling, thus achieving the heating effect.
By using a compressor to directly control the temperature of the laser, an intelligent temperature control system can achieve closed-loop control between the controlled object and the refrigeration system, allowing for precise cooling or heating as needed with low energy consumption. Compared with the traditional cooling method of water-cooled machines, there is no need for external heat exchange through coolant, no cooling water pollution, pipeline blockage and other advantages. The temperature control effect is better, maintenance free, and not afraid of adverse environmental effects.

Comparison of different heat dissipation methods

The core advantages of active air conditioning direct cooling technology

By combining the refrigeration unit and laser into one, the presence of water is eliminated, the intermediate thermal storage link is eliminated, the overall integration of the machine is higher, the volume and weight are smaller, and the cooling efficiency is better.
  • Ultra low power attenuation, stable performance
    The active air conditioning direct cooling technology relies on an intelligent temperature control system to ensure that the temperature of the laser chip does not exceed 70 ℃ during long-term operation at full power, and the annual power attenuation is as low as 5%.
  • Not afraid of extreme cold and heat, efficient heat dissipation
    Active air conditioning refrigeration technology adopts independent compressor direct cooling, with strong heat dissipation and adaptability to extreme weather conditions. GW Laser's innovative AAC intelligent temperature control technology ensures stable internal temperature of the laser and guarantees stable output.
  • Improve heat dissipation and break through power limits
    The increase in power of fiber lasers leads to a significant increase in thermal energy. At present, the maximum power of GW Laser air-cooled laser can reach 20kW, truly breaking through the bottleneck of heat dissipation technology for high-power lasers.

Understand GW's active air conditioning direct cooling fiber laser

GW Laser has successfully developed a 20kW active air conditioning direct cooling fiber laser, achieving a major breakthrough in heat dissipation technology and significantly improving power stability and operational convenience

Leave Your Message

We will reply you via email in 24 hours(Except holidays)

Follow GW

Copyright - 2021-2025 : All Rights Reserved. Hot Products - Sitemap

Phone:+86 4000-111-976

E-mail: sales@gwlaser.tech

Address: No. 8, 1st-3rd Floor, Building 8, 1388 Huazhi Road, Huaxin Town, Qingpu District, Shanghai